1. Check all parts before installation, and ensure that they conform to the drawings. During transportation, the whole and all parts and instruments have no deformation or damage.
2. The foundation of the hopper scale can not be installed on the platform with vibration source.
3. When the frame is installed, the three sensor seat plates should be leveled in the same horizontal plane.
4, the hopper scale installation must make the force through the axis of the sensor, the upper and lower ends of the support mode to prevent the introduction of additional external force interference.
5, the material door should open and close freely after installation, there is no stuck phenomenon.
6. Relevant control room facilities, cable laying and circuit installation positions shall be operated in accordance with relevant technical requirements.
7, hopper scale limit mechanism bolt and limit block should keep 2mm clearance.